Filter by engineering category to find the right plan package for your vessel or project.
IP-Protected
Mounting
Custom Gyro Mounting Bracket — SK6/SK9
PLAN-MT-001 • v2.1
Vessel-specific mounting bracket design for SK6 and SK9 gyro models. Adapted for 30-45ft center consoles and express cruisers.
- Full CAD drawings (PDF + DWG)
- Material specification sheet (316SS)
- Load calculation report
- Step-by-step installation instructions
- Compatible vessel list included
IP-Protected
Mounting
Custom Gyro Mounting Bracket — SK16/SK18
PLAN-MT-002 • v2.0
Mounting bracket design for SK16/SK18 models on 45-65ft sportfish and motor yachts. Includes vibration isolation system.
- Full CAD drawings (PDF + DWG)
- Vibration isolation spec
- Load calculation report
- Stringer interface detail
IP-Protected
Mounting
Custom Gyro Mounting Bracket — SK26
PLAN-MT-003 • v1.3
Heavy-duty mounting design for SK26 on 55-80ft yachts. Engineered for 1,200 lb static load with dynamic precession forces.
- Full CAD drawings (PDF + DWG)
- Reinforced mounting protocol
- CG impact analysis
- Crane lift plan included
IP-Protected
Foundation
Foundation Reinforcement Template — SK6/SK9
PLAN-FN-001 • v2.2
Stringer reinforcement engineering for 10-14" foundation cutouts. Prevents the 15% structural failure rate seen in unreinforced installations.
- Reinforcement layout drawings
- Fiberglass layup schedule (mat/woven roving)
- Stringer alignment verification protocol
- Post-cure inspection checklist
IP-Protected
Foundation
Foundation Reinforcement Template — SK16/SK18
PLAN-FN-002 • v2.0
Stringer reinforcement for 18-24" foundation cutouts on mid-size sportfish. Includes core replacement methodology.
- Reinforcement layout drawings
- Balsa core replacement detail
- Fiberglass layup schedule
- Tabbing pattern specification
IP-Protected
Foundation
Foundation Reinforcement Template — SK26/SK35
PLAN-FN-003 • v1.1
Heavy-duty foundation engineering for 24-30" cutouts on large yachts. Includes steel backing plate design.
- Steel backing plate CAD drawings
- Composite reinforcement schedule
- Multi-stringer load distribution
- Structural engineer stamp-ready
IP-Protected
Power
Power System Architecture — Single Gyro
PLAN-PW-001 • v2.3
Complete power system design for single-gyro installations. Battery bank sizing, alternator spec, and wiring diagram.
- System architecture schematic
- Load calculation worksheet
- Battery bank specification (AGM/Li/Sodium)
- Alternator upgrade guidance
- Cable sizing chart
IP-Protected
Power
Power System Architecture — Gyro + Interceptor
PLAN-PW-002 • v2.1
Dual-system power design for vessels with gyro + Humphree/Zipwake interceptors. Includes load sharing and priority management.
- Dual-bus architecture schematic
- Load priority matrix
- Battery bank specification
- Voltage sag prevention protocol
- Generator integration detail
IP-Protected
Power
Battery Upgrade Path — AGM to Sodium-Ion
PLAN-PW-003 • v1.2
Engineering design for AGM-to-sodium-ion battery conversion. Prevents 18-24 month failure cycles on high-load vessels.
- Conversion schematic
- Battery box modification drawings
- BMS integration diagram
- Charging system reconfiguration
IP-Protected
Integration
Multi-System Integration Schematic — Gyro + Humphree
PLAN-INT-001 • v2.0
NMEA 2000 network design for gyro + Humphree interceptor coordination. Shared sensor architecture and control interface.
- Network topology diagram
- Device address assignment
- Control logic specification
- Sea-trial validation protocol
IP-Protected
Integration
Multi-System Integration Schematic — Gyro + Zipwake
PLAN-INT-002 • v1.1
NMEA 2000 integration for gyro + Zipwake interceptor systems. Includes adaptive control tuning parameters.
- Network topology diagram
- Zipwake interface configuration
- Adaptive tuning guide
- Sea-state calibration protocol
IP-Protected
Corrosion
Corrosion Prevention Protocol — Full Vessel
PLAN-CR-001 • v2.4
Complete corrosion audit and prevention system design. Zinc anode layout, bonding system, and protective coating specification.
- Zinc anode placement diagram
- Bonding & grounding schematic
- Protective coating specification
- Annual inspection checklist
- Seawater system audit template
IP-Protected
Relocation
Gyro Removal & Structural Reinfill Engineering
PLAN-RL-001 • v1.5
Complete engineering package for safe gyro removal and structural reinfill. Includes cradle design and transport protocol.
- Removal sequence procedure
- Structural reinfill drawings
- Transport cradle design
- Hull integrity verification
IP-Protected
Relocation
Gyro Relocation Engineering Package
PLAN-RL-002 • v1.2
Full CG analysis and mounting design for gyro repositioning. Includes pre/post performance comparison framework.
- CG shift analysis worksheet
- New mounting location drawings
- Foundation comparison report
- Sea-trial comparison protocol
IP-Protected
Mounting
Dometic DG3 Custom Mounting Adapter
PLAN-MT-004 • v1.0
Mounting adapter design for Dometic DG3 active precession gyros on non-standard transom installations.
- Adapter plate CAD drawings
- Material specification
- Transom reinforcement detail
- Installation instructions
IP-Protected
Integration
Complete Installation Package — SK6/SK9 Vessel
PLAN-PKG-001 • v2.0
Full installation engineering package: mounting + foundation + power + integration. Everything needed for a complete SK6/SK9 install.
- All MT-001 + FN-001 + PW-001 + INT-001
- Project timeline template
- Yard coordination checklist
- Sea-trial validation protocol
- 10% bundle discount applied